Seitenansicht 8
GVD
HD
NVR/CMS
Release Note
9
# 6043: When the user opens Sony camera event detection on web, the HD NVR Manager
cannot detect motion alarm.
Workaround: Close the camera web page when the user needs to use the motion detection.
# 6109: In the MJPEG codec, Lilin IPD 5 series camera doesn’t support full D1 resolution.
# 6135: If the user set Etrovision main channel’s bitrate too high that will cause the sub channel
video streaming not stable.
Workaround: Reduce the main channel bitrate.
# 6148: If the bitrate is under 256K, the actual ADT: ADT-VSDB3MPTW’s video bitrate won’t be
synchronized.
Workaround: Set the bitrate higher than 256K.
# 6164: RIVA RE1000 video streaming is not stable if the user set the MJPEG quality too high.
Workaround: When the user use the MJPEG codec, set the quality not too high.
# 6182: In the some chance, RIVA RE1000 video streaming is not stable when the user enable
sub channel with RTP/RTSP and RTP over RTSP protocol.
# 6208: After deleting the camera channel which has displayed in the viewer, the viewer will
show “Searching Channel…, but not “No Video”.
# 6211: When playing Arecont 4 lens camera in the high speed mode (8x, 16x, 32x), some
streaming will be freeze.
# 6230: In the rare case, after enabling Pixord camera motion function it will cause video loss.
# 6212: Although FAN RPM is continually abnormal, but the alarm shows complete status after it
has been acknowledged by user.
# 6288: When the user focus at the right viewer in the panoramics mode, the left viewer will
show one more pixel line.
# In a rare case, volume creation may fail if the HDD was formatted by GVD Storage
Configuration Manager previously.
Seitenansicht 8